This window can be activated from the menu through →. The following image shows a screenshot of the ‘Network Manager’ of the XG5000 programming tool. See the Communication Configuration section for more information about the remaining parameters. This message box will close automatically after a few seconds. Otherwise (unchecked), Xpanel does not display a message for communication errors. Error Message Pop Up: When this item is checked, Xpanel displays a communication error message box for every Rx and Tx error.

The default setting of this option is the unchecked state.Ĭomm. In that case, this option can be applied.

To start using XPanel 5000 today, go to our Downloads section and download the latest version. Some PLCs have a limit on the number of TCP services. XPanel 5000 is an easy to use, drag and drop, instrument panel design program that enables even novice users to create airplane instrument panels like a pro. This option is provided for Xpanel to deal with various TCP port management ways of PLC. Otherwise, Xpanel will change the port at every TCP connection or communication error. Please verify your configuration (UDP or TCP) in the setup tab.ġ6Bit Data Swap: This field has no effect.ģ2Bit Data Swap: This field has no effect.įixed XPANEL Socket Port/XPANEL Socket Port No.: If this option was checked, Xpanel will use only one port defined in the 'XPANEL Socket Port No.' field for connection with the PLC. Socket Port No.: The socket number should be configured as 2005 for UDP and 2004 for TCP.

IP Address: Input the IP address of the PLC with a dotted-decimal format. Network ID: This field has no meaning in this driver (ignored during runtime). Station Type: Choose the ‘XGL-EFMT’ (no other type can be selected). This name will be used in the database window accompanied by the ‘Device Name’. ?host= 172.21.222.27& ipid=04&port=417940) All my eControls were connecting using IP ID they were compiled with, which was luckily IP ID of the Touch Panel, so they worked, but caused other issues.Station Name: Give a name to the PLC. I discovered that overriding IP ID in the link to eControl stopped working couple of years ago. Than compile it.įor a while now, I have to specify IP ID and port in VTProe even for web eControl hosted on Fusion. exe, you need to specify the connection settings in VTPro, IP of the processor, IP ID, and port 41794 usually. Then, if it's and Web XPanel, and you are using 2 series processor or DMPS3-4K-150, You need to put Core 3 XPanel Web Configuration Module v1.1 (from Crestron Modules Database) anywhere in the Simpl program, or it will not connect. You have to have a XPanel defined in your Simpl program, and have it at the same IP ID as your UI project. If you want to upload XPanel to the processor, and use processors web server to host it, make and upload XPanel 2.0 (Web) Smart Graphics.